ZBL-P8100 pile dynamic detector
1.features
l High fidelity system design, to ensure that the original waveform distortion:
l True 24 bit A/D data acquisition, the test waveform is more real, to avoid the noise and signal distortion caused by large floating point amplification;
l 1MHz high speed data acquisition, the minimum sampling time resolution of 1 μs, can provide more useful information, more conducive to the discovery of shallow defects;
l Double channel design, allows use the special detection method for the tested body do a nonconventional test, solve the unsolvable problems in conventional detection:
l A new processing method of wavelet analysis, can be more accurate in complex situations of pile integrity judgment:
l Double injection molding, beautiful appearance, small volume, light weight;
l Waterproof casing, anti shock design, adapt to the harsh environment:
l Semi transparent, high brightness, TFT color LCD screen, more clearly in the sun;
l Chinese and English bilingual switching.
2.field of use
By using the reflected wave method, the apparatus is used to assess the integrality of concrete pile and identify the extent and location of the pile defect. lt can be used for testing perfusion pile and hammer pile. It can also be used for testing the exposed top surface of constructions such as pillars.
3. specifications
| model | ZBL-P8100 |
| control mode | A8 embedded platform |
| screen | 5.7inch, high brightness, TFT color LCD screen |
| data storage | ≥4GB |
| operation mode | key & touch screen |
| Sentinel magnify | 1,2,5,10,20,50,100 adjustable |
| A/D resolution (bit) | true 24 bits A/D |
| sampling time intervals (μs) | 1-640000 adjustable |
| max. length of sampling | 4096 |
| trigger | signal trigger |
| noise voltage of the system (mV) | ≤1 |
| dynamic range(dB) | ≥184 |
| amplifier frequency range (Hz) | 10-10k |
| max. storage length | 4096 |
| amplitude nonlinear degree | ≤10% |
| time value error | |
| time resolving power (μs) | 1 |
| gain error (dB) | ≤1 |
| working time (h) | >8 |
| number of channels | 2 |
| interference between the channels | ≤1% |
| transducer / probe sensitivity (acceleration mode) (mv/g) | ≥100 |
| frequency range of probe (acceleration probe) (Hz) | 0.5-9000 |
| port | double USB |
| wifi | yes |
| internal power | built-in battery |
| external power | 220V AC/DC |
| weight | 1.3kg (lithium battery included) |
| size(mm) | 210x149x60mm |
| working environment | -10℃ to +50℃ <90%RH |