ZBL-C310A rebar rust detector
1. features
The C310A includes a two electrode handle system which provides flexibility for the operator to:
Test using one electrode based on half cell potential method.
Test using two electrodes based on gradient method. In both cases, electrodes used are copper sulfate type.
Automatic storage option is available in instrument.
Data transfer to USB-thumb drive is available.
The device generates rebars corrosion potential contour graph.
Software Provided for Data Processing of Corrosion Potential Measurement:Easy to Use Powerful processing software provided for generation of reports. Operates on windows based computers.
2. field of use
The C310A provides the ability to examine the corrosion potential and to localise active corrosion in rebar in building structures. The procedure is virtually non-destructive and is performed by carrying out a grid based measurement.
The C310A Rebar Corrosion Detector is a specialized apparatus designed according to the electrochemical testing method (natural potential method). C310A tests the potential of concrete surfaces through a Cu/CuSO4 reference electrode, and determines the level of rebar corrosion.
3.specifications
| item | specification | |
| corrosion detection method | single electrode | double electrode |
| measuring range | ±1000mV | 0-1000mV |
| accuracy | ±0.1mV | |
| tested points interval X | 0-100 adjustable | 20 fixed |
| tested points interval Y | 0-100 adjustable | 0-100 adjustable |
| screen | 160x128 | |
| working time | >40h | |
| power supply | built-in lithium battery | |
| data transmission | U disk | |
| data storage | 234 points | |
| size | 212x134x50mm | |
| electrode size | Φ30x180mm | |
| weight | 0.9kg | |